    High-temperature insulated wire ‘s no one-size-fits-all product. Based on the application, various factors will go into choosing the right kind of wire to find the job finished right. On this page, we’ll take particular notice at what these factors are and exactly how they can help in selecting the most appropriate high-temperature insulated wire to your specific situation.

    Factor #1: Concise explaination Electrical Requirements – Operating voltage, conductor temperature rating and current-carrying capacity (aka ampacity) must all be met when scouting for high-temperature insulated wire. Such wiring is labeled with a temperature rating, that is driven by a variety of ambient heat and current-generated heat. Ambient heat is a result of the application being performed whereas current-generated heat is calculated by matching conductor material and diameter to service amperage. It is important to note that due to difficulty in pinning down exact current-carrying capacity, manufacturers often specify higher capacity conductors than theoretical calculations would indicate.

    Factor #2: Environmental Conditions – What’s happening inside the wire isn’t the only consideration in terms of selecting the most appropriate high-temperature insulated wire. External environmental factors are also important. For they are able to have a damaging impact on the two wire’s insulation along with its interior circuitry. Ambient heat, moisture, abrasion, thermal stability, chemical attach, mechanical abuse, cold, flame resistance, easy stripping terminating and routing are typical environmental problems that should be compensated for when scouting for high-temperature insulated wire. A few of these factors are discussed in depth further on in this post.

    Factor #3: Conductor Material Type – The wire’s conductor material determine the maximum temperature it could withstand. Situations that require the wire to endure the very best of temperatures, like high-rise alarms in the event of a hearth, will be more reliably served with nickel-coated copper and nickel conductors, because both versions can endure temperatures around 550 degrees Celsius. Copper, nickel-plated and iron conductors conversely hold up under only a maximum selection of 200 to 250 degrees Celsius.

    Factor #4: Current-Carrying Capacity or Ampacity – A lot of the environmental conditions described above have an effect on high-temperature insulated wire’s capability to carry current. As a result, they ought to be weighed in to the equation. Ampacity is measured because the current a conductor can carry prior to the combined temperature of both conductor and insulation rises above a permitted limit.

    Conductor size and material, amperage, ambient temperature and insulation type will all may play a role is the wire’s ampacity. The conductor’s diameter and mass will be the most influential size considerations. Smaller they are, the lower the high-temperature insulated wire’s ampacity. As previously talked about inside the Factor #3 section, a conductor’s material has a strong relating the amount temperature the wire can withstand which temperature range varies widely. Likewise, various materials produce wide fluctuations within the current-carrying capacity from the wire also.

    Finally, the type of insulation used in the wire determines how much heat it dissipates and, in turn, the ampacity. The dissipation problem becomes even more complicated when wire is enclosed within a tightly confined space, so fire alarms in high-rise ductwork, as an example, pose additional challenges when looking for high-temperature insulated wire options.